HAZ-MAT BUILDING MODELS




Model
(1,2,5)
Nominal Outside
Dimensions
Interior
Sq Ft(3)
Designed
Storage
Capacity(3,4)
Total
Floor
Load (lbs)(3)
Sump
Capacity(3)
Tare
Weight(6)
P20
9' x 6' x 9'
29
6
7,250
126 Gals
6,000
P38
12' x 6' x 9'
45
8
11,250
196
8,000
P59
12' x 9' x 9'
69
16
17,250
301
10,000
P112
17' x 9' x 9'
114
28
28,500
497
14,000
P176
25' x 9' x 9'
178
44
44,500
776
17,500
W126
20' x 9' x 9'
127
30
31,750
554
13,000
W182
28' x 9' x 9'
186
48
46,500
811
18,000
W244
36' x 9' x 9'
243
64
60,750
1,086
23,000
W330
46' x 9' x 9'
329
88
82,250
1,435
30,000
P240
27' x 12' x 9'
252
60
63,000
1,099
23,000
P320
35' x 12' x 9'
336
80
84,000
1,466
30,000
P400
43' x 12' x 9'
420
100
105,000
1,832
35,000
P500
43' x 15' x 9'
480
120
120,000
2,094
40,000
P600
48' x 15' x 9'
552
138
138,000
2,408
45,000
             
NOTES:
Note 1: ANY BETWEEN-SIZE OR OVER-HEIGHT BUILDING MAY BE SPECIFIED.
Note 2: SPECIFY ONE OF THE FOLLOWING FIRE-RATINGS
(Applies where building permit is required for hazardous material storage):
-STL Non-fire-rated; more than 75 feet to property line or main building.
-FR2 Bi-directional 2 hour fire-rating; more than 10 feet to property line or main building.
-FR4 4 Hour fire-rating; 10 feet or less to property line or main building.
Note 3: Dimensions and capacities may vary with fire-rating and Optional Equipment installed.
Note 4: Drum capacity is stated as drums stored at one level. Drums may be double stacked where allowed.
Note 5: Standard door(s) are (WxH) 5' x 6'8". Optional door type, size, and quantity are available.
Note 6: Weight stated is that of an empty FR2 building; weight will vary with Optional Features specified.
Buildings meet or exceed all applicable UBC, SBC, BOCA National Building Codes, NFPA, UFC, EPA, NEC, CAC, OSHA, FM and UL codes with respect compliance in design; and meet or exceed all applicable ANSI, AWS, AISC, US Product, ASTM, WARNOCK-HERSEY, FM and UL standards regarding materials and workmanship.