| SUMMARY
OF OPTIONAL FEATURES and/or EQUIPMENT
AVAILABLE |
|
Following
is a summary of Optional Features and
Equipment available for Haz-Mat buildings.
Detail specifications may be requested
from Haz-Mat Containment. Other equipment
and options may be special ordered.
Some equipment or features may be incompatible,
and/or may reduce the available interior
space of the building. |
|
| Standard
Equipment and Features are not included in
this summary. |
| STANDARD
TYPES OF BUILDING |
-
Chemical Hazardous Material storage (flammables,
combustibles, acids, bases, oxidizers,
poisons)
-
Biological Hazardous Material storage
-
Low Level Radiological Hazardous Material
storage
-
Processing and Dispensing Hazardous Material
building
-
Gas Cylinder Storage
-
Secure Lock-up storage building
-
General storage building
-
Refrigerated storage building
|
| FIRE-RATED
BUILDING OPTIONS |
-
Non Fire-Rated;
welded steel construction; location should
be more that 75 feet from main building
or property line.
-
2 Hour Fire-Rated;
UL design, welded steel construction;
location should be more than 10 feet from
main building or property line.
-
4 Hour Fire-Rated;
UL design, welded steel construction;
location should be more than 5 feet from
main building or property line.
|
EXPLOSION
RELIEF CONSTRUCTION
includes explosion relief panels (blow-out
panels), security bars, tethering the panels,
insulation when building is insulated. |
|
|
OVER
STANDARD HEIGHT BUILDINGS:
Building can be manufactured to a nominal
10' or more to accommodate an automatic sprinkler
system; bridge crane or other customer requirement.
|
|
|
DOORS:
All standard doors are 7 Ft. high and include
a rain guard. Other types and/or sizes may
be ordered. |
- Swing
Doors:
Also include astragal, threshold, safety
lever and lock.
- Fire-doors:
3', 5' or 8' wide. Also include automatic
door closure and are 3 hour fire-rated;
UL and/or Warnock Hersey listed.
- Steel
doors: 4'6" or 9' wide.
-
Roll-up Doors
include standard hand operated opener.
- Fire-doors:
5', 9' wide.
-
Steel doors:
5', 9' wide.
- Explosion
proof opener.
-
Hardware: All
doors include door threshold, rain guard,
astragal lever lock assembly (swing doors
only), automatic door closures (fire-doors
only).
Optional hardware include the following:
- Panic
Hardware
- Door
coordinator and door closure
for inactive leaf of swing double
doors.
- Dead
Bolt locks
- Security
Locks
- Fusible
link door hold open closure
- Manual
door hold open
|
| INTERIOR
SEPARATION WALLS |
-
Solid welded steel separation wall
-
Hour fire-rated separation wall
- Vented
separation wall
- Moveable
separation wall
|
|
SUMP OPTIONS |
-
Sump separation
wall
-
Sump drain
- Sump
overflow
|
|
HVAC OPTIONS |
|
|
- Passive
Ventilation (cross floor passive ventilation
is included as standard equipment)
- Electro-Mechanical;
explosion proof fan assembly.
- Additional
Fire-rated vent,
air inlet/outlet vent (includes fire-damper)
- Additional
non fire-rated vent,
air inlet/outlet vent
- Electro-Mechanical
EP vent,
automatic opening and closing explosion
proof vent
- Roof
Turbine Vent
- EP
Fume Extractor,
explosion proof fume extractor, includes
counter balanced arm and hose
- EP
Fume Hood,
overhead vent hood and explosion proof
exhaust fume evacuation system
|
|
|
- EP
12,300 BTU Heater,
explosion proof heater and interior
thermostat
- EP
26,000 BTU Heater,
explosion proof heater and interior
thermostat
- EP
52,000 BTU Unit Heater,
explosion proof fan forced heater and
interior thermostat
|
- AIR
CONDITIONING, UL or ETL listed
|
- 14,000
BTU C1D2 AC,
hazardous location air conditioner,
Class 1 Div 2
- 19,000
BTU C1D2 AC,
hazardous location air conditioner,
Class 1 Div 2
- 19,000
BTU C1D1 AC,
Approved hazardous location air conditioner,
Class 1 Div 1
- 36,000
BTU C1D1 AC,
Approved hazardous location air conditioner,
Class 1 Div 1
|
|
|
- Walls,
sump walls and ceiling
- Walls,
sump walls, ceiling and subfloor
|
| FIRE
SUPPRESSION SYSTEMS |
-
Automatic Dry
Chemical, includes exterior
weather proof enclosure, alarm and remote
contacts. UL listed.
-
Backup Sprinkler Assembly
-
Backup Sprinkler
Assembly with Fire Department Connection
(FDC)
-
Automatic Sprinkler System,
includes alarm and all check and bypass
valves. Over Height building and Sump
may be required.
-
25# ABC Extinguisher,
hand held 25# ABC dry chemical fire extinguisher
-
5# ABC Extinguisher,
hand held 5# ABC dry chemical fire extinguisher
|
| LIGHTING
OPTIONS |
-
Interior EP Light,
300 watt explosion proof lights with exterior
switch
-
Exterior Light,
exterior photocell activated light
-
Exterior EP Light,
exterior mounted explosion proof light
-
Skylight,
roof mounted skylight, double dome
|
| RECEPTACLES
and SWITCHES |
-
EP Single Gang,
explosion proof single gang, interior
or exterior
-
EP Double Gang,
explosion proof double gang, interior
or exterior
-
Non EP Double Gang non
explosion proof double gang
-
EP Switch,
explosion proof light or fan switch
|
| HDPE
SUMP LINER, high density polyethylene
sump liner (sump has standard epoxy coating) |
| |
| ALARMS |
-
Fire Alarm bell
(included when ordering Automatic Dry
Chemical Fire Suppression or Sprinkler
System
-
EP Spill Detector,
explosion proof spill detector installed
in sump
-
Power Failure
Alarm
-
EP Rate of Rise Heat Detector,
explosion proof detector, includes alarm
bell
-
EP Sensor System:
Explosion proof sensor and monitor system
with alarm and remote annunciation capability.
Specify material, such as low level oxygen,
gasoline etc.
|
| RAISED
FLOOR |
-
Epoxy/Wood,
slip resistant surfaced epoxy coated floor
with front grate to channel spills allows
for easy clean-up and use of hand trucks.
- Steel
Grating, heavy duty bar grating
- Fiberglass
grating
|
| MATERIAL
HANDLING EQUIPMENT |
-
Loading Ramp
-
Pallet Racks
-
Drum Conveyor,
can be installed instead of raised floor
wherever required
-
Roller Floor,
for pallets or drums can be installed
instead of raised floor wherever required.
-
Pallet Turntable
-
Bridge Crane
-
Jib Crane
|
| SAFETY
STATIONS |
-
Safety Shower/Eye Wash:
Emergency drench shower and eye/face wash;
must be plumbed; approved.
-
Safety Eye Wash:
Self contained systems; approved.
|
| MISCELLANEOUS
EQUIPMENT |
-
Gas Cylinder Rack, single size
-
Gas Cylinder
Rack, double size
-
Grounding Bars,
installed inside building. (Interior grounding
connections and exterior building ground
system included with building as standard
equipment)
-
Lifting Eyes, installed
to lift building. (Standard crane/fork
pockets are installed on all buildings)
-
Color choice,
choice of standard polyurethane colors.
(Gloss white is standard color and is
included unless a color choice is specified)
|
| |
|
|
| Buildings
meet or exceed all applicable UBC, SBC, BOCA
National Building Codes, NFPA, UFC, EPA, NEC,
CAC, OSHA, FM and UL codes with respect compliance
in design; and meet or exceed all applicable
ANSI, AWS, AISC, US Product, ASTM, WARNOCK-HERSEY,
FM and UL standards regarding materials and
workmanship.
|