Contact HazMat HazMat Client List About HazMat
Haz-Mat Containment. Manufacturers of safety storage buildings, lockers for storage, dispensing, processing chemical, flammable, radioactive and biological hazardous materials.
  Construction | Transporting | Std. Features | Opt. Features | Bldg. Models | Sump & Pallet Models


HAZ-MAT OPTIONAL FEATURES

.
SUMMARY OF OPTIONAL FEATURES and/or EQUIPMENT AVAILABLE
Following is a summary of Optional Features and Equipment available for Haz-Mat buildings. Detail specifications may be requested from Haz-Mat Containment. Other equipment and options may be special ordered. Some equipment or features may be incompatible, and/or may reduce the available interior space of the building.
Standard Equipment and Features are not included in this summary.
STANDARD TYPES OF BUILDING
  • Chemical Hazardous Material storage (flammables, combustibles, acids, bases, oxidizers, poisons)
  • Biological Hazardous Material storage
  • Low Level Radiological Hazardous Material storage
  • Processing and Dispensing Hazardous Material building
  • Gas Cylinder Storage
  • Secure Lock-up storage building
  • General storage building
  • Refrigerated storage building
FIRE-RATED BUILDING OPTIONS
  • Non Fire-Rated; welded steel construction; location should be more that 75 feet from main building or property line.
  • 2 Hour Fire-Rated; UL design, welded steel construction; location should be more than 10 feet from main building or property line.
  • 4 Hour Fire-Rated; UL design, welded steel construction; location should be more than 5 feet from main building or property line.
EXPLOSION RELIEF CONSTRUCTION
includes explosion relief panels (blow-out panels), security bars, tethering the panels, insulation when building is insulated.

 

OVER STANDARD HEIGHT BUILDINGS:
Building can be manufactured to a nominal 10' or more to accommodate an automatic sprinkler system; bridge crane or other customer requirement.

 

DOORS:
All standard doors are 7 Ft. high and include a rain guard. Other types and/or sizes may be ordered.
  • Swing Doors: Also include astragal, threshold, safety lever and lock.
    • Fire-doors: 3', 5' or 8' wide. Also include automatic door closure and are 3 hour fire-rated; UL and/or Warnock Hersey listed.
    • Steel doors: 4'6" or 9' wide.
  • Roll-up Doors include standard hand operated opener.
    • Fire-doors: 5', 9' wide.
    • Steel doors: 5', 9' wide.
    • Explosion proof opener.
  • Hardware: All doors include door threshold, rain guard, astragal lever lock assembly (swing doors only), automatic door closures (fire-doors only). Optional hardware include the following:
    • Panic Hardware
    • Door coordinator and door closure for inactive leaf of swing double doors.
    • Dead Bolt locks
    • Security Locks
    • Fusible link door hold open closure
    • Manual door hold open
INTERIOR SEPARATION WALLS
    • Solid welded steel separation wall
    • Hour fire-rated separation wall
    • Vented separation wall
    • Moveable separation wall
SUMP OPTIONS
    • Sump separation wall
    • Sump drain
    • Sump overflow
HVAC OPTIONS
  • VENTILATION OPTIONS
    • Passive Ventilation (cross floor passive ventilation is included as standard equipment)
    • Electro-Mechanical; explosion proof fan assembly.
    • Additional Fire-rated vent, air inlet/outlet vent (includes fire-damper)
    • Additional non fire-rated vent, air inlet/outlet vent
    • Electro-Mechanical EP vent, automatic opening and closing explosion proof vent
    • Roof Turbine Vent
    • EP Fume Extractor, explosion proof fume extractor, includes counter balanced arm and hose
    • EP Fume Hood, overhead vent hood and explosion proof exhaust fume evacuation system
  • HEATING, UL listed
    • EP 12,300 BTU Heater, explosion proof heater and interior thermostat
    • EP 26,000 BTU Heater, explosion proof heater and interior thermostat
    • EP 52,000 BTU Unit Heater, explosion proof fan forced heater and interior thermostat
  • AIR CONDITIONING, UL or ETL listed
    • 14,000 BTU C1D2 AC, hazardous location air conditioner, Class 1 Div 2
    • 19,000 BTU C1D2 AC, hazardous location air conditioner, Class 1 Div 2
    • 19,000 BTU C1D1 AC, Approved hazardous location air conditioner, Class 1 Div 1
    • 36,000 BTU C1D1 AC, Approved hazardous location air conditioner, Class 1 Div 1
  • INSULATION
    • Walls, sump walls and ceiling
    • Walls, sump walls, ceiling and subfloor
FIRE SUPPRESSION SYSTEMS
  • Automatic Dry Chemical, includes exterior weather proof enclosure, alarm and remote contacts. UL listed.
  • Backup Sprinkler Assembly
  • Backup Sprinkler Assembly with Fire Department Connection (FDC)
  • Automatic Sprinkler System, includes alarm and all check and bypass valves. Over Height building and Sump may be required.
  • 25# ABC Extinguisher, hand held 25# ABC dry chemical fire extinguisher
  • 5# ABC Extinguisher, hand held 5# ABC dry chemical fire extinguisher
LIGHTING OPTIONS
  • Interior EP Light, 300 watt explosion proof lights with exterior switch
  • Exterior Light, exterior photocell activated light
  • Exterior EP Light, exterior mounted explosion proof light
  • Skylight, roof mounted skylight, double dome
RECEPTACLES and SWITCHES
  • EP Single Gang, explosion proof single gang, interior or exterior
  • EP Double Gang, explosion proof double gang, interior or exterior
  • Non EP Double Gang non explosion proof double gang
  • EP Switch, explosion proof light or fan switch
HDPE SUMP LINER, high density polyethylene sump liner (sump has standard epoxy coating)
 
ALARMS
  • Fire Alarm bell (included when ordering Automatic Dry Chemical Fire Suppression or Sprinkler System
  • EP Spill Detector, explosion proof spill detector installed in sump
  • Power Failure Alarm
  • EP Rate of Rise Heat Detector, explosion proof detector, includes alarm bell
  • EP Sensor System: Explosion proof sensor and monitor system with alarm and remote annunciation capability. Specify material, such as low level oxygen, gasoline etc.
RAISED FLOOR
  • Epoxy/Wood, slip resistant surfaced epoxy coated floor with front grate to channel spills allows for easy clean-up and use of hand trucks.
  • Steel Grating, heavy duty bar grating
  • Fiberglass grating
MATERIAL HANDLING EQUIPMENT
  • Loading Ramp
  • Pallet Racks
  • Drum Conveyor, can be installed instead of raised floor wherever required
  • Roller Floor, for pallets or drums can be installed instead of raised floor wherever required.
  • Pallet Turntable
  • Bridge Crane
  • Jib Crane
SAFETY STATIONS
  • Safety Shower/Eye Wash: Emergency drench shower and eye/face wash; must be plumbed; approved.
  • Safety Eye Wash: Self contained systems; approved.
MISCELLANEOUS EQUIPMENT
  • Gas Cylinder Rack, single size
  • Gas Cylinder Rack, double size
  • Grounding Bars, installed inside building. (Interior grounding connections and exterior building ground system included with building as standard equipment)
  • Lifting Eyes, installed to lift building. (Standard crane/fork pockets are installed on all buildings)
  • Color choice, choice of standard polyurethane colors. (Gloss white is standard color and is included unless a color choice is specified)
 
Buildings meet or exceed all applicable UBC, SBC, BOCA National Building Codes, NFPA, UFC, EPA, NEC, CAC, OSHA, FM and UL codes with respect compliance in design; and meet or exceed all applicable ANSI, AWS, AISC, US Product, ASTM, WARNOCK-HERSEY, FM and UL standards regarding materials and workmanship.




Contact Us | Client List | About Us | QUICK QUOTE

Construction | Transporting | Standard Features | Optional Features | Building Models | Sump & Pallet Models

Home Page | Building Pictures | Equipment Pictures | GSA
© 1999-2007 Haz-Mat Containment
3480 Buskirk Ave. Ste 210 Pleasant Hill Ca, 94523